A fractional CO2 laser machine is an advanced medical beauty equipment, which uses a 10,600-nanometer pixelated beams to create a micro-therapeutic area in the skin or mucosa, which promotes the remarkable remodeling of collagen and reduces downtime. Key factors to be considered in the selection include its power output (such as the 60 w model discussed), scanning mode, safety certifications (CE, FDA, ISO) and expected application-from facial rejuvenation and scar treatment to vaginal regeneration. The correct choice depends on the technical specifications of the equipment, such as spot size, pulse modes and scanning range, to meet your specific needs.

A fractional CO2 laser machine is a sophisticated medical-aesthetic device that emits a 10,600 nm wavelength laser beam in a pixelated or “fractionated” pattern. Instead of treating the entire surface area, it creates a grid of microscopic thermal injuries surrounded by untreated, healthy tissue. The staged treatment method creates a micro-treatment area (mtz), which significantly speeds up the healing process by allowing the surrounding healthy tissue to promote rapid repair. This process effectively stimulates the production of new collagen and elastin fibers, which are the cornerstone of skin remodeling. The mechanism of step-by-step photolysis and its influence on collagen synthesis are well documented in dermatological literature. ( Source: https://pubmed.ncbi.nlm.nih.gov/15373777/ )
It is very important to understand the technical specifications of fractional CO2 laser machine when evaluating it. The following is a detailed list of typical 60 W model.
| Specification Category | Detail |
| Wavelength | 10600nm |
| Laser apparatus | Sealed off laser device simulated by direct current |
| Optical beam quality | TEM00 |
| Output power | 60w |
| Spot size | 0.02~0.05mm2 |
| Aiming beam | Red semiconductor laser (635nm, less than 5mw) |
| Beam transport device | Articulated arm with 6-joint and balance weight |
| Working mode | Continuous operation |
| Output Mode | Continuous, single pulse, interval pulse and super pulse |
| Scan scope | Max 20mmx20mm |
| Scan graphics | Circle, triangle, square, rectangle,hexagon, ellipse, line |
| Scanning Mode | Random , Normal and Midsplit scan |
| Scanning speed | More than 10m/s |
| Energy | 1- 40W |
| Distance | 0.1-2.6mm |
| Cooling system | air circulation |
| Weight | 60kg |
| Dimension | 65*48*117cm |
| Power | 220V/11V |
Before clinical use, it is recommended to conduct a test on a 4 paper first. The depth of skin tissue is approximately equal to the thickness of a piece of A4 paper; Excessive energy will cause excessive damage to the skin. This test method is helpful for operators to accurately grasp the energy output of the CO2 laser machine for skin, and to avoid adverse reactions during formal treatment.
In this industry, fractional CO2 laser is mainly used for skin surface reconstruction, wrinkle removal, pigmentation treatment and scar repair. Medical and beauty institutions, dermatological clinics and plastic surgery hospitals are the main application places. The deep tissue permeability of the device can effectively stimulate collagen regeneration, improving skin texture and reducing deep wrinkles, and it is recognized as the gold standard for skin surface reconstruction.
CO2 laser machine for skin (with vaginal treatment mode) is used for vaginal tightening, improving dryness and other gynecological problems. By generating controlled heat at 50-70℃ in the vaginal mucosa, the regeneration of fibroblasts and the reorganization of collagen can be stimulated, and the vaginal wall can be thickened and tightness enhanced. This application is growing rapidly, and more and more gynecological clinics use this technology for non-invasive vagina rejuvenation.
In anti-aging-focused beauty salons, a CO2 laser resurfacing machine is used to improve skin texture, enhance elasticity, and reduce fine lines. Its non-ablation treatment mode ensures the least downtime, making it popular among middle-aged and young customers who are pursuing mild anti-aging treatments. Although the market share is relatively small, with the increasing demand of consumers for high-end skin care, it is showing a gradual expansion trend.
There are significant differences between fractional CO2 laser machine and Er: YAG laser processing machine on the market, especially in function, cost and service life. The following is a detailed comparison based on industry test data and market survey.
Er:YAG lasers focus more on improving the skin’s surface and are not as powerful as CO2 fractional lasers in deep repair.
However, because the effect may not be as obvious as that of the CO2 laser machine on the skin, more treatment periods may be needed to achieve the desired effect, thus increasing long-term costs.
In summary, CO2 fractional laser machines offer superior deep-penetration treatment capabilities, making them suitable for a variety of complex skin issues. However, they have higher initial investment and treatment costs, and a longer lifespan. Er:YAG laser devices, on the other hand, offer advantages in terms of initial investment and treatment costs, making them suitable for rapid treatment of surface-level problems. However, their functionality is relatively limited, and their lifespan is also shorter. The choice of appropriate device depends on specific needs and the target customer group.
| Fault Information | Fault Cause and Troubleshooting |
| No display when instrument is powered on | 1. Instrument not connected to AC power: Check if the power cord is plugged into the power outlet, if the main power control switch and emergency stop switch are turned on, and if all connection sockets are properly connected; 2. Low-voltage switching power supply fault: Check if the input and output sockets of the low-voltage switching power supply are normal; 3. Control board faulty; 4. LCD display faulty |
| Foot switch malfunction | 1. The foot switch is not properly connected; 2. The foot switch is damaged and needs to be replaced |
| High voltage power supply failure | 1. High-voltage power supply is not powered or main SSR is faulty; 2. High-voltage power supply is faulty and needs to be replaced |
| When the switch key is turned to the “ON” position, the instrument does not perform any operation | 1. No AC power supply connected; 2. Emergency stop switch not activated; 3. Main control switch on rear panel not activated; 4. Low-voltage power supply damaged or main control board malfunctioning |
| The aiming indicator light is too weak | 1. Rotate the aiming light adjustment knob; 2. Too much dust has accumulated on the lens of the light guide system, it needs to be cleaned or the light guide arm replaced; 3. The semiconductor laser is damaged and needs to be replaced. |
| CO2 does not fall on the aiming beam spot | Optical path offset |
| When the instrument is in the ready state, there is no air blowing | 1. The air pump is not connected to 220V AC power; 2. The air hose is not properly connected; 3. The air pump is damaged and needs to be replaced; 4. Other electrical faults |
| No CO2 laser emission occurs when the foot switch is pressed. | 1. Poor contact in the foot switch wiring; 2. Instrument not in ready state; 3. Damaged laser tube; 4. High-voltage power supply failure; 5. Other electrical faults |
| Power cannot be calibrated | 1. Control panel malfunction; 2. Optical path misalignment; 3. Laser tube has been used for too long; 4. Control board malfunction; 5. High-voltage power supply or laser tube malfunction; 6. Other electrical fault |
A 1: Patients should avoid using certain drugs (such as aspirin and other anticoagulants) before treatment. The doctor will need to ask patients about their history of allergies or skin condition. A comprehensive evaluation should be carried out before treatment to ensure the applicability of laser treatment.
A 2: The time of recovery varies from person to person. Redness, swelling, and scaling are usually present within 3-7 days after treatment. Most patients can resume their normal activities within one week, but specific situations should be in accordance with the doctor’s advice.
A 3: CO2 fraction laser machine is suitable for the treatment of various skin problems, including wrinkles, acne scars, pigmentation, sagging skin and large pores.
A 4: The duration of treatment effects depends on individual differences, skin type and skin care procedures. Generally speaking, after several treatments, the effects can last for 1-2 years, depending on individual’s lifestyle and skin care habits.
A 5: The service life of CO2 laser equipment is usually 5 to 10 years, depending on the frequency of use, maintenance, brand and model of the equipment.
With the steady growth of the global market for CO2 fractional laser system, the adoption of standardized high-performance CO2 laser dermatome will help organizations gain competitive advantages in the developing market.A fractional CO2 laser machine is a multifunctional and efficient medical beauty equipment, which plays a vital role in solving deep skin and vagina problems. Its core advantages are accurate treatment, wide application range and high patient acceptance. It is an important investment for medical and aesthetic institutions pursuing high-quality development. When choosing equipment, medical institutions should give priority to parameter matching, certification compliance and supplier ability to ensure clinical safety and operational efficiency.